歡迎訪問濟南金昊化工有限公司網站!
全國咨詢熱線:13869119097

聯系我們

濟南金昊化工有限公司

電話:13869119097

傳真:0531-88529097

售后:0531-88529097

地址:濟南市天橋區桑梓店鎮化工市場南區

新聞中心

所在位置:首頁 > 新聞中心 

氫氧化鉀檢測的細節與注意的地方

發布來源:http://m.ileleli.cn    更新時間:2023-01-31 點擊數:33

檢驗氫氧化鉀中要確定樣品的采樣單元數。采樣器由袋口的一角斜到袋深的3/4處采樣,將采出的樣品混勻,用四分法縮分到所要檢驗的樣品量。
The number of sampling units of the sample shall be determined in the test of potassium hydroxide. The sampler slants from one corner of the bag mouth to 3/4 of the bag depth for sampling, mixes the collected samples evenly, and reduces them to the amount of samples to be tested by quartering.
因氫氧化鉀肥料吸水性強,故在制備樣品時動作應迅速。樣品制備后,稱取5g試樣,到0.001g,加入150ml水,然后在不斷攪拌下加熱,微沸5min,取下冷卻到20℃,移入500ml容量瓶,定容過濾后再吸取25.0ml于250.0ml的容量瓶中。這是一個很關鍵的環節。
Because potassium hydroxide fertilizer has strong water absorption, it should be rapid when preparing samples. After sample preparation, weigh 5g of sample to 0.001g, add 150ml of water, and then heat it under constant stirring, slightly boil it for 5min, take it down and cool it to 20 ℃, transfer it into a 500ml volumetric flask, filter at constant volume, and then suck 25.0ml into a 250.0ml volumetric flask. This is a key link.
有一些檢驗員為了一時方便,不是在水溫達到20℃時定容,而按常溫的水溫定容,結果是水溫高于20℃時,結果偏高;水溫低于20℃時,結果偏低。兩次定容造成兩次誤差,所以,準確的檢驗溫度是檢驗結果準確與否的關鍵。水溫高于20℃的檢驗結果與20℃時的檢驗結果比較見表1。
For temporary convenience, some inspectors do not fix the volume when the water temperature reaches 20 ℃, but according to the normal temperature. The result is that when the water temperature is higher than 20 ℃, the result is higher; When the water temperature is lower than 20 ℃, the result is low. Two times of constant volume cause two times of error, so the accurate test temperature is the key to the accuracy of the test results. See Table 1 for the comparison of the test results when the water temperature is higher than 20 ℃ and the test results when the water temperature is 20 ℃.
氫氧化鉀
在弱堿性介質中,四苯硼鈉[NaB(C6H5)4]堿性溶液和洗滌液對檢驗結果有直接影響。因為配制好的四苯硼鈉很不穩定,容易產生渾濁。如果使用前發現有混濁,要用中速濾紙過濾后再使用,否則檢驗結果偏高。用洗滌液洗滌和用蒸餾水洗滌檢驗,結果也不一樣。有些檢驗員認為配制洗滌液麻煩,用蒸餾水代替洗滌液,檢驗結果就會偏低。蒸餾水的原始結果與洗滌劑的正確結果相關數據比較見表1。
In weakly alkaline medium, sodium tetraphenylboron [NaB (C6H5) 4] alkaline solution and washing solution have a direct impact on the test results. Because the prepared sodium tetraphenylboron is unstable and easy to produce turbidity. If turbidity is found before use, it should be filtered with medium speed filter paper before use, otherwise the test result is on the high side. The results of washing with detergent and distilled water are also different. Some inspectors think it is troublesome to prepare washing solution. If distilled water is used instead of washing solution, the test result will be low. See Table 1 for the comparison between the original results of distilled water and the correct results of detergent.
檢驗中,試液過濾后的洗滌步驟存在洗滌終點不夠明確的問題。依據GB6549-1996《氫氧化鉀》規定,先抽濾上清液,再用洗滌液(即室溫下飽和的四苯硼鉀溶液)轉移沉淀過濾器中,繼續用以上洗滌液洗滌沉淀12次左右,每次洗滌液用量約為5ml。
During the test, there was a problem that the washing end point was not clear enough in the washing step after the test solution was filtered. According to the provisions of Potassium Hydroxide (GB6549-1996), the supernatant is filtered first, and then the washing solution (i.e. potassium tetraphenylborate solution saturated at room temperature) is transferred to the filter for precipitation. The above washing solution is used to wash and precipitate for about 12 times, and the amount of washing solution is about 5ml each time.
如果檢驗員做不夠洗滌次數,在干燥后的坩堝上就能清晰見到粉紅色的物質,這是未洗滌盡的氫氧化鈉與酚酞產生的物質顏色,終將導致鉀含量偏高。因此,洗滌次數均不應低于12次。洗滌次數少于12次的原始結果與不少于12次的正確結果比較見表1。
If the inspector does not wash enough, the pink substance can be clearly seen on the dried crucible. This is the color of the substance produced by the unwashed sodium hydroxide and phenolphthalein, which will eventually lead to a high potassium content. Therefore, the washing times should not be less than 12 times. See Table 1 for the comparison between the original results of less than 12 times of washing and the correct results of no less than 12 times.
總結一下在氫氧化鉀產品的主含量氧化鉀檢驗中,對幾個關鍵環節必須給予足夠的重視,對可能產生誤差的各種因素要加以避免和克服,才能保證檢驗結果的準確度。
To sum up, in the test of potassium oxide in the main content of potassium hydroxide products, sufficient attention must be paid to several key links, and various factors that may cause errors must be avoided and overcome to ensure the accuracy of the test results.
以上闡述的就是氫氧化鉀檢測的細節與注意的地方,希望我的分享對你們有所幫助,如果還想了解更多相關內容請繼續關注我們網站http://m.ileleli.cn,后期我們也會發布更多相關咨詢。當然有什么不懂的地方歡迎您前來電話咨詢。
The above is the details and points for attention of potassium hydroxide detection. I hope my sharing will help you. If you want to know more, please continue to pay attention to our website http://m.ileleli.cn , we will also release more relevant consultation later. Of course, if you don't understand anything, you are welcome to call.

聯系我們

濟南金昊化工有限公司

電話:13869119097

傳真:0531-88529097

售后:0531-88529097

地址:濟南市天橋區桑梓店鎮化工市場南區

掃描二維碼,關注我們

13869119097

全國客戶服務熱線

濟南金昊化工有限公司

備案號:魯ICP備19046505號-2
主站蜘蛛池模板: 女人操男人 | 亚洲日韩爆乳中文字幕欧美 | 久久精品免费视频6 | 丰满妇女强制高潮18xxxx | 国产h视频免费观看 | 天堂8在线新版官网 | 欧美在线观看视频 | 精品一久久香蕉国产线看播放 | 91精品国产综合久久久久久 | 品色堂免费论坛 | 九九热免费在线视频 | 在线欧美69v免费观看视频 | 久久免费精品高清麻豆 | 韩国特级一级毛片免费网站 | 韩国成人在线观看 | 国产福利兔女郎在线观看 | 国精产品一品二品国在线 | 小箩莉末发育娇小性色xxxx | 久草最新视频 | 91久久综合九色综合欧美亚洲 | 青青久在线视频免费观看 | 久99久精品视频免费观看v | 国产精品久久在线观看 | 国产精品va无码一区二区 | 国内精品久久久久久久久久久久 | ww国产ww在线观看免 | 亚洲天堂久久精品 | 丰满五十六十老熟女hd | 亚洲精品久久久久久久久久吃药 | 丰满的少妇愉情hd高清果冻传媒 | av国产剧情md精品麻豆 | 免费看啪啪网站 | 精品国产免费一区二区三区 | 精品不卡一区二区 | 美女免费污网站在线播放 | 国产成+人+亚洲+欧美+日韩 | 国产精品揄拍一区二区久久 | 日本黄色片网址 | 亚洲人成无码网站 | 99ri在线视频 | 欧美精品国产一区二区三区 |